Dell PowerEdge 2650 User Manual

Page 12

Advertising
background image

E07FA

TEMP CPU n

THERM

Specified microprocessor is out of
acceptable temperature range and is
operating at a reduced speed, or
frequency.

Ensure that the system cooling fans are properly installed. If the problem persists,
replace the faulty fan(s) (see "

System Fans

"). If the problem persists, ensure that the

microprocessor heat sinks are properly installed. If the problem persists, replace the
faulty microprocessor (see "

Microprocessors

").

E0876

POWER PS n

No power available from the specified
power supply; specified power supply is
improperly installed or faulty.

Ensure that the power supplies are properly installed. If the problem persists, replace
the faulty power supply(s) (see "

Power Supplies

").

E0880

INSUFFICIENT

PS

Insufficient power is being supplied to the
system; power supplies are improperly
installed, faulty, or missing.

E0CB2

MEM SPARE

BANK

Correctable errors threshold was met in a
memory bank: errors were remapped to
the spare bank.

Ensure that the memory modules are properly installed. If the problem persists,
replace the faulty memory module(s) (see "

Memory Modules

").

E0CF1

MBE DIMM

Bank n

Memory modules installed in the specified
bank are not the same type and size;
faulty memory module(s).

Ensure that all banks contain memory modules of the same type and size and that
they are properly installed. If the problem persists, replace the faulty memory module
(s) (see "

Memory Modules

").

E0CF1

POST MEM 64K

Parity failure in the first 64 KB of main 
memory.

Ensure that the memory modules are properly installed. If the problem persists,
replace the faulty memory module(s) (see "

Memory Modules

").

E0CF1

POST NO

MEMORY

Main-memory refresh verification failure.

Ensure that all banks contain memory modules of the same type and size and that
they are properly installed. If the problem persists, replace the faulty memory module
(s) (see "

Memory Modules

").

E0CF5

LOG DISABLE

SBE

Multiple single-bit errors on a single
memory module.

Ensure that the memory modules are properly installed. If the problem persists,
replace the faulty memory module(s) (see "

Memory Modules

").

E0D76

DRIVE FAIL

Faulty or improperly installed hard drive or
RAID controller.

Ensure that the hard drives are properly installed. If the problem persists, replace the
faulty hard drive(s) (see "

Hard Drives

"). If the problem persists, replace the RAID

controller (see "

Integrated RAID Controller

" and "

RAID Controller Card

").

E0F04

POST CMOS

CMOS write/read failure; faulty system
board.

Replace the system board (see "

System Board

").

E0F04

POST CPU

SPEED

Microprocessor speed control sequence
failure.

Ensure that the microprocessors are properly installed. If the problem persists,
replace the faulty microprocessor(s) (see "

Microprocessors

").

E0F04

POST DMA

INIT

DMA initialization failure; DMA page
register write/read failure.

Ensure that the memory modules are properly installed. If the problem persists,
replace the faulty memory module(s) (see "

Memory Modules

").

E0F04

POST DMA REG

Faulty system board.

Replace the system board (see "

System Board

").

E0F04

POST KYB

CNTRL

Faulty keyboard controller; faulty system
board.

Replace the system board (see "

System Board

").

E0F04

POST MEM

RFSH

Main-memory refresh verification failure.

Ensure that the memory modules are properly installed. If the problem persists,
replace the faulty memory module(s) (see "

Memory Modules

").

E0F04

POST PIC REG

Master or slave PIC register test failure.

Replace the system board (see "

System Board

").

E0F04

POST SHADOW

BIOS-shadowing failure.

Ensure that the memory modules are properly installed. If the problem persists,
replace the faulty memory module(s) (see "

Memory Modules

").

E0F04

POST SHD

TEST

Shutdown test failure.

E0F04

POST SIO

Super I/O chip failure; faulty system
board.

Replace the system board (see "

System Board

").

E0F04

POST TIMER

Programmable interval timer test failure;
faulty system board.

Replace the system board (see "

System Board

").

E0F0B

POST ROM

CHKSUM

Faulty or improperly installed expansion
card.

Ensure that the expansion cards are properly installed. If the problem persists,
replace the faulty expansion card(s) (see "

Expansion Cards

").

E0F0C

VID MATCH

CPU n

Specified microprocessor is faulty,
unsupported, improperly installed, or
missing.

Ensure that the microprocessors are properly installed. If the problem persists,
replace the faulty microprocessor(s) (see "

Microprocessors

").

E10F3

LOG DISABLE

BIOS

BIOS disabled logging errors.

Check the SEL for details on the errors.

E13F2

IO CHANNEL

CHECK

Faulty or improperly installed expansion
card; faulty system board.

Ensure that the expansion cards are properly installed. If the problem persists,
replace the faulty expansion card(s) (see "

Expansion Cards

"). If the problem persists,

replace the system board (see "

System Board

").

E13F4

PCI PARITY

E13F5

PCI SYSTEM

E13F8

CPU BUS INIT

Faulty or improperly installed
microprocessor or system board.

Ensure that the microprocessors are properly installed. If the problem persists,
replace the faulty microprocessor(s) (see "

Microprocessors

"). If the problem persists,

replace the system board (see "

System Board

").

E13F8

CPU BUS

PARITY

Faulty system board.

Replace the system board (see "

System Board

").

E13F8

CPU MCKERR

Machine check error; faulty or improperly
installed microprocessor; faulty system
board.

Ensure that the microprocessors are properly installed. If the problem persists,
replace the faulty microprocessor(s) (see "

Microprocessors

"). If the problem persists,

replace the system board (see "

System Board

").

E13F8

HOST BUS

Faulty system board.

Replace the system board (see "

System Board

").

E13F8

HOST TO PCI

BUS

E13F8

MEM

CONTROLLER

Faulty or improperly installed memory
module; faulty system board.

Ensure that the memory modules are properly installed. If the problem persists,
replace the faulty memory module(s) (see "

Memory Modules

"). If the problem

persists, replace the system board (see "

System Board

").

E1580

POWER

CONTROL

Faulty system board.

Replace the system board (see "

System Board

").

E20F1

OS HANG

Operating system watchdog timer timed
out.

Restart your system. If the problem persists, see your operating system
documentation.