Before Starting the Configuration Process

Before you start configuring the storage array or host connectivity, it is recommended that you fill out the
iSCSI configuration worksheet to help you plan your configuration. You may need to use several
worksheets depending on your configuration.
Keep the following guidelines in mind for the storage array and host configuration:

• For optimal performance, ensure your network configuration. See the storage array's Support Matrix

at dell.com/support/manuals.

• If your host has multiple network interfaces, it is recommended that each network interface uses a

separate subnet.

• For redundancy in a dual controller (duplex) configuration, ensure each host network interface is

configured to connect to both storage array controllers.

• For optimal load balancing, ensure each host network interface that is used for iSCSI traffic is

configured to connect to each storage array controller.

• It is recommended that each host network interface only establishes one iSCSI session per storage

array controller.

NOTE: The utility tries to follow the guidelines for the host connectivity whenever possible based on
the available host network interfaces and their connectivity with the iSCSI host ports of the storage
array.

Configuring the Storage Array Using MDCU

To configure the iSCSI-based storage array(s) using the MDCU:

NOTE: For more information on MDCU, see the MDCU online help.

1.

Launch the utility (if it is not launched automatically) from the server with access to the management

ports of the storage array(s) to be configured.

– For Windows, click Start → All Programs → Dell → MD Storage Software.
– For Linux, click the MDCU icon on the desktop or navigate to the /opt/dell/mdstoragesoftware/

mdconfigurationutility directory in a terminal window and run PowerVault MDCU.

The MDCU automatically discovers all the available storage arrays.

2. In the Discover MD Arrays window, select the iSCSI storage array you want to configure.
3. In the Selected Array window, review current port and session information.
4. Click Config Wizard, to start the iSCSI configuration wizard.
5. Complete the steps in Config Wizard to configure your iSCSI storage array.
6. In the Array Configuration Summary window, review and apply your configuration settings.
7. Click Create iSCSI Sessions, to create host-to-storage array communication.

Repeat for all host-to-array mappings you want to implement.

8. Verify that communication is established between the storage array and host server.

NOTE: For more information on MDCU, see the MDCU online help.

Post Connection Establishment Steps

After iSCSI connectivity is established between the host server(s) and the storage array, you can create