Dell powervault md-series storage array rules – Dell PowerVault MD3820f User Manual

Page 6

Advertising
background image

6

Dell PowerVault MD-Series Storage Array Rules

This section contains both general and model-specific connectivity and consideration rules
for MD storage arrays. Only the rules shown in

Table 2

apply to ALL storage array models. For

rules applying to specific MD models, see

Tables 3 and 4

.

Table 2. MD-Series Storage Array Rules for All Models

NOTE: MD3460, MD3860i and MD3860f platforms are supported in

dual-RAID controller (duplex) configurations only.

MD3400

Series

MD3800i

series

MD3800f

series

RULE

12Gbps

SAS

10Gbps

iSCSI

16Gbps

Fibre

Channel

Maximum number of host servers a single storage array can

connect to with one RAID Controller Module installed

4

64

64

Maximum number of host servers a single storage array can

connect to with two RAID Controller Modules installed

8

(4 if using

high

availability)

64

64

Maximum number of Dell 12Gb SAS HBA cards supported in a

single host server attached to single array. (It is recommended to

use two Dell 12Gb SAS HBA cards for all redundant cabling

configurations.)

2

(each card

has two

ports)

N/A

N/A

Unused ports on a Dell 12Gb SAS HBA card already connected to

an MD3460 cannot be connected to another device (such as a

tape drive or other model storage array).

N/A

N/A

Maximum number of MD Series Storage Arrays a host server

may connect to:

2 (HA)

4

4

SAS and iSCSI storage arrays can be connected to the same host
server.

The I/O co-

existence

between the

Fibre Channel
and any other

protocol on

same host is

not supported.

A hot spare for a disk group must be a physical disk of equal

or greater size than any of the member disks.