 Processor 1 internal error

 Processor 2 internal error

Defective microprocessor or system board
(reported by the NMI handler).

 

Replace the specified microprocessor. See
"

Microprocessors

." If the problem persists, replace the

system board. See "

System Board

."

 Processor 1 is a 533-MHz system bus processor

 Processor 2 is a 533-MHz system bus processor

Two 533-MHz microprocessors are
installed. This system supports only
Intel® Xeon™ 400-MHz front-side-bus
processors.

Reboot the system. If you receive beep code 4-4-3
(processor frequency mismatch), replace both processors
with Intel Xeon 400-MHz front-side-bus processors. See
"

Microprocessors

."

If a beep code does not occur at system boot, turn off the
system, install the NVRAM_CLR jumper, and reboot the
system. See

Figure 5

-2

for jumper location.

 Processor bus error

 PCI bus error

 IMB bus error

Defective system board (reported by the
NMI handler).

Replace the system board. See "

System Board

."

 Processor x is not a 533-MHz system bus

processor

 This system bus speed is not supported on this

system board

This system supports only Intel Xeon 533-
MHz front-side bus (system bus)
processors.

Reboot the system. If you receive beep code 4-4-3
(processor frequency mismatch), replace processor x with
a supported processor. See "

Microprocessors

."

If a beep code does not occur at system boot, turn off the
system, install the NVRAM_CLR jumper, and reboot the
system. See

Figure 5

-2

for jumper location.

 Read fault

 Requested sector not found

Faulty diskette, diskette-drive subsystem,
or hard-drive subsystem.

Replace the diskette. Reseat all drives and reboot the
system. If the message reappears, replace the diskette
drive. See "

Installing a Diskette Drive

." If the problem

persists, replace the system board. See "

System Board

."

 Reset failed

Improperly connected diskette/tape drive,
hard drive, or power cable.

Check the drive and cable connections, and reset the
system again.

 ROM bad checksum = address

Expansion card improperly installed or
faulty.

Reinstall the expansion card. See "

Expansion Cards

." If

the problem persists, replace the expansion card.

 Sector not found

 Seek error

 Seek operation failed

Defective sectors on diskette or hard
drive.

Faulty diskette, diskette-drive subsystem,
or hard-drive subsystem.

Replace the diskette, or reseat all drives and reboot the
system. See "

Installing a Diskette Drive

" or "

Internal SCSI

Hard Drives

." If the message reappears, replace the drive

(s). If the problem persists, replace the system board.
See "

System Board

."

 Shutdown failure

Defective system board.

Replace the system board. See "

System Board

."

 System backplane error

Improperly attached or missing SCSI
backplane.

Reseat the SCSI backplane. See "

SCSI Backplane Board

."

 System halted! Must power down.

Wrong password entered too many
times.

Reboot the system and enter the correct password. If the
problem persists, see "

Disabling a Forgotten Password

."

 System parity error

Defective expansion card(s) or improperly
seated or faulty memory modules
(reported by the NMI handler).

Replace the expansion cards one at a time until the error
is corrected. See "

Expansion Cards

."

Remove and reseat the memory modules. See "

Memory

."

If the problem persists, replace the memory modules. If
the problem persists, replace the system board. See
"

System Board

."

 The following memory DIMMs are unsupported:

DIMM_xx.

 This system only supports 266 MHz DIMMs.

One or more of the installed DIMMs has a
frequency less than 266 MHz. System
memory must be rated for 266 MHz. 

Replace lower-speed DIMM(s) with modules rated for 266-
MHz operation. See "

Memory

."

 This processor system bus speed is unknown.

 System halted!

The installed microprocessor is not
supported by the system.

Reboot the system. If you receive beep code 4-4-3
(processor frequency mismatch), replace the installed
microprocessor(s) with microprocessor(s) supported by
your system. See "

Microprocessors

."

If a beep code does not occur at system boot, turn off the
system, install the NVRAM_CLR jumper, and reboot the
system. See

Figure 5

-2

for jumper location.

 This system only supports 400-MHz system bus

speed.

 System halted!

Two 533-MHz microprocessors are
installed. This system supports only Intel
Xeon 400-MHz front-side-bus processors.

Reboot the system. If you receive beep code 4-4-3
(processor frequency mismatch), replace both processors
with Intel Xeon 400-MHz front-side-bus processors. See
"

Microprocessors

."

If a beep code does not occur at system boot, turn off the
system, install the NVRAM_CLR jumper, and reboot the
system. See

Figure 5

-2

for jumper location.

 Time-of-day clock stopped

Defective battery or faulty chip (defective
system board).

Replace the system battery. See "

System Battery

." If the

problem persists, replace the system board. See "

System

Board

."

 Time-of-day not set - please run SETUP program

Incorrect Time or Date settings or
defective system battery.

Check the Time and Date settings. See "

Using the

System Setup Program

." If the problem persists, replace

the system battery. See "

System Battery

." If the problem

persists, replace the system board. See "

System Board

."

 Timer chip counter 2 failed

Defective system board.

Replace the system board. See "

System Board

."

 Unsupported CPU combination

Microprocessor combination is not
supported by the system.

Install a supported microprocessor combination. See
"

Microprocessors

."

 Unsupported CPU stepping detected.

Microprocessor is not supported by the
system.

Install the correct version of the microprocessor in the
specified microprocessor socket. See "

Microprocessors

."

 Utility partition not available

<F10> key was pressed during POST, but Create a utility partition on the boot hard drive. See