Initial system configuration, Before you begin, Power requirements – Dell POWEREDGE M1000E User Manual

Page 27: Network information, Initial setup sequence

Advertising
background image

Initial System Configuration

27

2

Initial System Configuration

Before You Begin

Power Requirements

CAUTION:

The enclosure power supplies must be connected to a Type B or

permanently-connected PDU and not directly to an electrical outlet. The power
supplies require a 100–120 V or 200–240 V power source. You can select only one
AC power input, as the system does not operate at both ranges simultaneously.

Network Information

If your network uses static addressing, you need the IP address, subnet mask,

and gateway to configure the CMC and other modules in the enclosure.

Initial Setup Sequence

1 Unpack the enclosure and install it in a rack.

For more information, see the Getting Started Guide and Rack Installation

Guide at support.dell.com/manuals.

CAUTION:

Do not turn on the blades (server modules) until you have configured

the switch modules, as described in "Configuring the I/O Modules" on page 47.

2 Connect the power supply units to a PDU.
3 If an optional iKVM module is installed, connect the keyboard, video, and

mouse to the enclosure control panel (see Figure 1-4) or to the iKVM

module (see Figure 1-16).

NOTE:

Connecting a keyboard, video, and mouse to the enclosure front panel

disables video output to the iKVM back panel port.

4 Press the power button on the enclosure control panel. See Figure 1-4.

book.book Page 27 Wednesday, March 9, 2011 3:11 PM