Dell PowerVault NX1950 User Manual
Page 8
 
Disk
¡
Group: Choose Cluster Group
6.
Click Next.
7.
Verify that all cluster nodes are in the
Possible Owners window and click 
Next. 
8.
Select the following dependencies:
¡
Cluster IP Address
¡
Cluster Name
¡
Physical Disk of Choice
9.
Click Add and then click Next.
10.
Complete the wizard and then click
Finish.
11.
Right-click Resource and choose
Online. The disk is now a part of the 
cluster. 
12.
In the Share and Storage Management
window, refresh the Volumes tab.
The Share Provision wizard 
allows a share to be created in 
an existing shared folder 
without displaying a warning 
that the current file settings 
may be erased 
The Share and Storage Management wizard allows you to create a new 
shared folder in an existing shared folder without warning that this may 
erase the File Screen settings of the existing shared folder. 
The File Screen setting for all shares in the Share tab of the Share and 
Storage Management wizard is checked. However, only the last File 
Screen setting is applied to the share. 
This is a known issue.
Long failover time on the 
PowerVault MD3000 storage 
array 
The PowerVault NX1950 storage solution supports redundant paths 
through a single or dual Serial-Attached SCSI (SAS) Host Bus Adapter 
(HBA) controller. When you configure the PowerVault NX1950 storage 
solution to support a redundant path through a single controller, the 
failover takes a longer time during heavy input/output. However, there is 
no loss of data due to a delay in failover. 
For more information, see the Knowledge Base 
article 940467 at the Microsoft Support 
website at support.mircosoft.com. 
Uninstalling and Reinstalling 
File Server Resource Manager 
displays two consoles in the 
PowerVault NX1950 
Management Console 
When you uninstall and reinstall File Server Resource Manager one 
console is displayed under the Share and Storage Management wizard 
and the other console is displayed under PowerVault NX1950 
Management Console. 
You can ignore the snap-in that appears below 
PowerVault NX1950 Management Console. 
LUN type for a failed over 
volume in a cluster is displayed 
as Simple 
In the Share and Storage Management wizard, all volumes that failover 
are displayed as Simple. 
To refresh the RAID type:
1.
In the second node where the volumes
are displayed as Simple, go to Disk 
Management. 
2.
Go to Share and Storage
Management® Volumes and click
Refresh.
LUN type for volume displayed 
as unknown in a cluster 
The LUN type for volumes created from the passive node in a cluster is 
displayed as unknown in the Share and Storage Management wizard of 
the active node. 
Go to the Disk Management window and 
perform a refresh. Go back to the Share and 
Storage Management wizard and perform a 
refresh. All the LUNs are now displayed 
properly. 
Reverting the shadow copies in 
Microsoft Cluster Services fails 
An error message is displayed when reverting a shadow copy of volume 
that is a part of a cluster group. 
Remove the volume from the cluster resources 
and revert the shadow copy.After a successful 
revert, add the volume back to the cluster 
group. For more information, see the 
knowledge base article KB945361 on the 
Microsoft Support website at 
support.microsoft.com. 
Launching the Share Provision 
wizard after uninstalling the 
File Server Resource Manager 
results in a storagemgmt.dll 
console error. 
If you run the Share Provision wizard from Share and Storage 
Management wizard after uninstalling the File Server Resource Manager 
using Add or Remove Programs, the following error message is 
displayed: 
Unhandled exception in managed code snap-in
Share and Storage Management wizard is removed from the PowerVault 
NX1950 Management Console. 
To reinstall the File Server Resource Manager 
perform the following steps: 
1.
Go to Control Panel® Add or Remove
Programs® Add or Remove Windows 
Components® Management and 
Monitoring Tools. 
2.
Select File Server Resource Manager.
NOTE:
After reinstalling the File Server
Resource Manager, the PowerVault NX1950 
Management Console shows two similar 
consoles. 
The Storage Manager for 
SANs console does not remove 
the available drive letters 
assigned to a volume. 
When two Create LUN operations are performed in rapid succession, the 
Storage Manager for SANs console does not remove the available drive 
letters. This issue is indicated by an error message related to volume 
creation failure. 
To work around this issue, use the Disk 
Management console to create volumes 
manually or wait for a few seconds for the 
used drive letter to be removed from the 
Storage Manager for SANs console. 
Deleted drives or volumes in 
the Disk Management console 
cause the system to crash. 
After you delete a volume through the Storage Manager for SANs 
console, the volume continues to display under the Disk Management 
console. If you select the deleted volume, the PowerVault NX1950 
Management Console crashes. 
To avoid this issue, use the Share and 
Storage Manager console to delete the 
volume. 
VDS errors are reported in the 
Windows application log. 
While creating or deleting LUNs, the following error message is reported in 
the Windows application log: 
Storage Manager for SANs encountered the following error(s) while
loading information from Virtual Disk Service (VDS) or VDS hardware
provider(s). Some of the functionality may not be available on the
hardware provider(s).
To work around this issue, set the password 