25

Power GPGPU Slots On/Off To Clear Device Error “code 43”

The following table lists the IPMIUTIL raw command to switch on/off each GPGPU.

Example1. If GPGPU slot1 gets “code 43” error

GPGPU SLOT 01 to switch on/off

1. Power off GPGPU cards by ipmiutil command.

#

Type “ipmitool -I lanplus -H” 192.168.0.120” -U”root” -P”root” raw 0x30 0xf0

01

00”

2. Power on GPGPU cards by ipmiutil command, typing the same command again will switch

current status.

#

Type “ipmitool -I lanplus -H” 192.168.0.120” -U”root” -P”root” raw 0x30 0xf0

01

00”

3. Reboot the HOST by ipmitool command or other method of Remote control.

#./ipmitool -I lanplus -H”HOST IP address” -U”root” -P”root” chassis power reset.

4. The “code 43” error disappears after HOST reboot.