Dell PowerEdge C410x User Manual

Page 26

Advertising
background image

26

Example2. If GPGPU slot9 gets “code 43” error

GPGPU SLOT 09 to switch on/off

1. Power off GPGPU cards by ipmiutil command.

#

Type “ipmitool -I lanplus -H” 192.168.0.120” -U”root” -P”root” raw 0x30 0xf0 00

01”

2. Power on GPGPU cards by ipmiutil command, typing the same command again switchs

current status.

#

Type “ipmitool -I lanplus -H” 192.168.0.120” -U”root” -P”root” raw 0x30 0xf0 00

01”

3. Reboot the HOST by ipmitool command.

#./ipmitool -I lanplus -H”HOST IP address” -U”root” -P”root” chassis power reset.

4. The “code 43” error disappears after HOST reboot.

Example3. If GPGPU slot16 gets “code 43” error

GPGPU SLOT 16 to switch on/off

1. Power off GPGPU cards by ipmiutil command.

#

Type “ipmitool -I lanplus -H” 192.168.0.120” -U”root” -P”root” raw 0x30 0xf0 00

80”

2. Power on GPGPU cards by ipmiutil command, typing the same command again switchs

current status.

#

Type “ipmitool -I lanplus -H” 192.168.0.120” -U”root” -P”root” raw 0x30 0xf0 00

80”

3. Reboot the HOST by ipmitool command or other method of Remote control.

#./ipmitool -I lanplus -H”HOST IP address” -U”root” -P”root” chassis power reset.

4. The “code 43” error will be disappeared after HOST reboot.