Table 1-59. Configuration ID = 11h, Power Management

Attribute

ID Size Description

R/W

Power

Staggering AC

Recovery

2

1

This parameter is only effective if the Power Policy

is not set to always off.

• 0x00: Immediate Power On (No Delay) (default)
• 0x01: Auto (Random), the auto generated delay

time must be in the range of Minimum Power On

Delay and Maximum Power On Delay.

• 0x02: User Defined, the user defined delay time

must be in the range of Minimum Power On

Delay and Maximum Power On Delay.

R/W

Power On Delay 3

2

Define the time to delay power on the system after

AC recovered and BMC firmware ready.
Default value is 00h.

R/W

Minimum

Power On Delay

4

2

Specify the minimum power on delay in seconds,

when AC is restored and BMC firmware ready.

This does not include the BMC firmware setup

time.
Default value is the time in seconds for BMC

firmware to boot and ready to accept and perform

Power On command.

R

Maximum

Power On Delay

5

2

Specify the maximum power on delay in seconds,

when AC is restored. The number must be greater

than Minimum Power On Delay.
Default value is the Minimum Power On Delay

+1 second.