Outback Power Systems MATE2 User Manual

Page 122

Advertising
background image



Go to the GRIDUSE screens in the ADVANCED menu. Using these screens, you can set the

times of day you want to use grid AC power and the times you want to stop using it. This allows

you connect when your batteries will not adequately supply all your loads or take advantage of

lower utility rates at certain times of the day.

• griduse enable: turns this mode on or off

• weekday griduse start: establishes the weekday time the FX Series Inverter/Charger connects

to the grid

• adj hour and adj min: these screens adjust the time

• weekday griduse stop: establishes weekday time the FX will disconnect from grid power

• weekend griduse start: user can set weekend time to connect to the grid

• weekend griduse stop: user can set weekend time to disconnect from grid

For further adjustments, go to the GRID screens in the ADVANCED menu:

• acl/grid lower limit—sets the minimum grid-supplied voltage the FX will connect to

• acl/grid upper limit—sets the maximum grid-supplied voltage the FX will connect to

• acl/grid input limit—the maximum amperage the FX can draw from the grid

You can manually start a generator manually or by presetting some time, voltage, or load

conditions. To manually start a generator:

• Press the AC IN hot key twice (on the left side of the MATE)

• Press the <ON> soft key

To preset generator start-up conditions, go to the AGS (Advanced Generator Start) screens in

the ADVANCED menu and do the following for time-based start and stops:

• Press <SETUP>

• Choose the appropriate HUB port

• AGS enabled—press <YES>

• Choose from <AUTO> or <ON> to start

• If <AUTO> is chosen, conditions can be set to start the generator

• <ON> is a manual start

Further AGS settings:

• weekday quiet time start—weekday early time you do not want generator to start

• adj hour & adj min—establishes the exact start time when generator should not be running

• weekday quiet time stop—ends the quiet period, generator can run again

• adj hour & adj min—establishes exact stop time

• Same adjustments are available for weekends

How to connect to an electrical grid

How to start my generator

Advertising
This manual is related to the following products: