Troubleshooting the system, Troubleshooting, The system – Dell PowerVault 220S (SCSI) User Manual

Page 16

Advertising
background image

Basic Troubleshooting : Dell PowerVault 220S and 221S Systems Service Manual

file:///C|/Users/rishi_sood/Desktop/220s/en/sm/basics.htm[3/7/2013 12:09:14 PM]

For a list of all SCSI hard-drive LED flash patterns, including the ones described previously, see

Table 3

.

To troubleshoot your SCSI hard drives, complete the following steps:

1. Is the storage system turned off?

Yes. Turn on the storage system using the on/off switch on the back of the power supply (see

Figure 8

for switch

location).

No. Go to step 2.

2. Is the SCSI cable(s) damaged or not attached securely to the SCSI connectors on the EMM(s) and the host controller?

No. Go to step 3.

Yes. Secure the cable(s) or check connector pins for damage.

3. Does the bus configuration switch mode match your cabling configuration? For example, if you are operating in split-bus

mode, is the cabling between the host(s) and the storage system appropriate for this mode? (For more information on

cabling configurations, see your Installation and Troubleshooting Guide.)

Yes. Go to step 4.

No. Change either the bus configuration switch mode or cabling between the host and storage system. Then reboot the

storage system and the host.

4. Are the status LED indicators for all the hard drives illuminated?

Yes. End troubleshooting.

No. Go to step 5.

5. If a hard drive's status indicator is off, reseat the hard drive by removing it from its drive bay and reinstalling it (see

"

Removing and Installing Hard Drives

"). Is the problem resolved?

Yes. End troubleshooting.

No. Install a new hard drive.

NOTICE:

Replacing the hard drive in a non-RAID system will cause all data on that drive to be lost. Only replace the hard

drive when using a supported host adapter card. See your system's readme file for a list of supported cards.

Troubleshooting the System

When the storage system is turned on, the system performs a POST, which checks the system components. During POST, the

indicators for each SCSI hard drive blink briefly, and the front-panel indicators are illuminated (see

Figure 2

). When the POST

completes, the indicators are illuminated as described in

Table 2

.

When a problem exists with the storage system, one or more of the following events occur:

Amber shelf fault LED is illuminated

Audible alarm sounds (when enabled)