System Overview : Dell PowerVault 220S and 221S Systems Service Manual

file:///C|/Users/rishi_sood/Desktop/220s/en/sm/intro.htm[3/7/2013 12:09:13 PM]

Table 1. Front Panel Indicators

LED Indicator LED Icon Condition
Power (green)

At least one power supply is supplying power to the system.

Shelf-fault

(amber)

One of the following conditions has occurred: power-supply failure, EMM failure, cooling-module failure, over-temperature condition, split-bus module not

installed, or firmware currently being downloaded. For more information, see "

Basic Troubleshooting

."

Cluster (green)

The system is configured for cluster mode. For more information, see "

Split-Bus Module

."

Split-bus

(green)

The system is configured for split-bus mode. For more information, see "

Split-Bus Module

."

Over-

temperature

(amber)

An over-temperature condition has occurred (the system will shut down when the temperature inside the box exceeds 50°C [122°F]). For more

information, see "

Basic Troubleshooting

." For the locations of the temperature probes, see "

Temperature Probes

."

Hard-Drive Carrier LED Indicators

Each of your storage system's 14 hard-drive carriers has two LED indicators: a busy indicator and a status indicator (see

Figure 2

for location).

Table 2

shows the hard-drive LED

indicators with the associated LED icons.

Table 3

lists the flash patterns for the hard-drive status indicator.

Table 2. Hard-Drive Carrier LED Indicators

LED Indicator

LED Icon

Condition

Busy (green)

The hard drive is active on the SCSI bus.

NOTE:

This LED is controlled by the hard drive.

Status (green and amber)

See

Table 3

for flash patterns and conditions.

Table 3. Hard-Drive Carrier Status Indicator Flash Patterns

Condition

Status Indicator Pattern

Slot empty, ready for insert/remove

Off

Drive online, prepare for operation

Steady green

Drive identify

Flashes green four times per second

Prepare for removal

Flashes green twice per second at equal intervals

Drive rebuild

Flashes green twice per second at unequal intervals

Drive fail

Flashes amber four times per second

Predicted failure

Flashes green, then amber, then off, repeating this sequence every two seconds

Back-Panel Features and Indicators

Figure 3

illustrates the back-panel features for systems with redundant EMMs and redundant power supplies.

Figure 4

illustrates the back-panel features for nonredundant systems. See

Figure 5

,

Figure 6

, and

Figure 8

for more detail on the back-panel indicators.

Figure 3. Back-Panel Features (Systems With Redundant EMMs and Redundant Power Supplies)

1 unused port
2 cooling module (blowers 2 and 3)
3 power supply (PSU1)
4 power supply (PSU2)
5 cooling module (blowers 0 and 1)
6 unused port