Environmental

NOTE: For information on supported expanded
operating temperature range and configurations, see
support.dell.com/manuals.

Storage

-40–65 °C -(40–149 °F) with a maximum temperature
gradation of 20 °C per hour

Relative humidity

Operating

10% to 80% (noncondensing) at a maximum wet bulb
temperature of 26 °C (79 °F)

Storage

5% to 95% (noncondensing) at a maximum wet bulb
temperature of 33 °C (91 °F)

Maximum vibration

Operating

0.26 Grms at 5–350 Hz (all operation orientations)

Storage

1.87 Grms at 10–500 Hz for 15 min (all six sides tested)

Maximum shock

Operating

One shock pulse in the positive z axis (one pulse on each
side of the system) of 31 G for 2.6 ms in the operational
orientation

Storage

Six consecutively executed shock pulses in the positive
and negative x, y, and z axes (one pulse on each side of
the system) of 71 G for up to 2 ms
Six consecutively executed shock pulses in the positive

and negative x, y, and z axes (one pulse on each side of

the system) of 32 G faired square wave pulse with

velocity change at 270 inches/second (685 centimeters/

second)

Altitude

Operating

-15.2–3048 m -(50–10,000 ft)

NOTE: For altitudes above 2950 ft, the maximum
operating temperature is derated 1 ºF/550 ft.

Storage

-15.2–10,668 m -(50–35,000 ft)

NOTE: The system can be air shipped.

Particulate Contamination

Air Filtration

Data center air filtration as defined by ISO Class 8 per
ISO 14644-1 with a 95% upper confidence limit.

NOTE: Air entering the data center must have
MERV11 or MERV13 filtration.