3. Fault LED. The front panel of your Dell PowerVault LTO4-120HH tape drive has an amber fault LED indicating the drive has encountered an error, is not in a
normal operational status, or needs cleaning. See table 1 for more detailed description.

4. Single-character display. This LED presents a single-character code for diagnostic/maintenance functions, error conditions, and informational messages.

5. Single red dot. This single-character display is blank during normal operation. When a single red dot illuminates and flashes on the display, the drive has created a
dump of vital technical data to drive memory.

 

Table 1. SCD, Ready/Activity LED, and Fault LED Descriptions

Rear Panel

 

Figure 4. Rear Panel of Internal SAS Tape Drive

1. SAS connector

 

Figure 5. Rear Panel of External SAS Tape Drive

Condition of green
Ready/Activity LED

Condition of amber
Fault LED

Condition of the
SCD Panel

Condition of the
SCD Dot

Meaning of LEDs and SCD Panel and SCD Dot

Off

Off

Off

Off

The tape drive has no power or is powered
off.

On Solid

Off

Off or

Off

The tape drive is powered on or (if a solid

displays in the single character display)

needs cleaning.

Flashing once per
second

Off

Off

Off

The tape drive is reading from the tape,
writing to the tape, rewinding the tape,
locating data on the tape, loading the tape,
or unloading the tape. The Ready/Activity
LED also flashes green if the tape drive
contains a cartridge during the power on
cycle. In this case, the drive completes
POST and slowly rewinds the tape (this
process may take approximately 13
minutes). The Ready/Activity LED stops
blinking when the drive completes the
recovery and is ready for a read or write
operation. To eject the cartridge, press the
unload button.

Off

On/Solid

On Solid

On/Off

The tape drive is in maintenance mode or is
displaying an error code on the SCD in
maintenance mode option 9.

Off

On Solid

Flashing once
per second

On/Off

Executing the selected option while in
maintenance mode.

Off

Flashing once
per second

On Solid

Off

An error occurred and the tape drive or
media may require service or drive may
require cleaning. Note the code on the single
character display, and then go to the error
code table in the troubleshooting section to
determine the meaning of the error codes. If
a

appears on the SCD, a cleaning

cartridge must be loaded.

Off

Flashing twice
per second

Off

Off

The drive is updating firmware.

Off

Flashing once
every 2
seconds

Off

Off

The drive detected an error and is
performing a firmware recovery. It will reset
automatically.