Dell Powervault DL2300 User Manual

Page 113

Advertising
background image

Error Code

Message Information

Action

Remove and reinstall the power supply at the next service window. If
the issue persists, see

Getting Help

.

PSU0003

Message

The power input for power supply <

number

> is lost.

Details

The power supply is installed correctly but an input source is not
connected or is not functional.

Action

Verify the input source is attached to the power supply. Verify the
input power is within the operating requirements for the power
supply.

PSU0006

Message

Power supply <

number

> type mismatch.

Details

Power supplies should be of the same input type and power rating.

Action

Install matched power supplies and review proper configuration in
this manual.

PSU0016

Message

Power supply <

number

> is absent.

Details

The power supply has been removed or has failed.

Action

1. Remove and reinstall the power supply.
2. Check cables and subsystem components in the system for

damage.

3. If the issue persists, see

Getting Help

.

PSU0031

Message

Cannot communicate with power supply <

number

>.

Details

The power supply may operate, however power supply monitoring is
degraded. System performance may be degraded.

Action

Remove and reinstall the power supply. If the issue persists, see

Getting Help

.

PSU0032

Message

The temperature for power supply <

number

> is in a warning range.

Details

System performance may be degraded.

Action

Check the system operating environment, including airflow and inlet
temperature. Check system logs for temperature and thermal
component failures.

PSU0033

Message

The temperature for power supply <

number

> is outside of the

allowable range.

113