Current monitoring, Fan control and monitoring – Dell PowerEdge C5220 User Manual
Page 22
Advertising

22
Current Monitoring
BMC supports current sensor as shown in Table 1-11. The current sensor
monitoring aims to gain the SLED power consumption for power
management used.
FAN Control and Monitoring
The BMC receives all fan tachometers of the threshold base from the chassis
controller. The following is the table of the fan speed thresholds.
Table 1-11. Current Monitoring
Current
Sensor Number
UNCT
UCT
SLED 12V
0x4E
216
252
Table 1-12. Fan Thresholds
Fan Sensor
Sensor
Number
LCT
LNCT
SYS FAN 1
0x68
600 rpm
720 rpm
SYS FAN 2
0x69
600 rpm
720 rpm
SYS FAN 3
0x6A
600 rpm
720 rpm
SYS FAN 4
0x6B
600 rpm
720 rpm
SYS FAN 5
0x6C
600 rpm
720 rpm
SYS FAN 6
0x6D
600 rpm
720 rpm
SYS FAN 7
0x6E
600 rpm
720 rpm
SYS FAN 8
0x6F
600 rpm
720 rpm
Advertising