Client network connections (public network), Cluster interconnects (private network) – Dell PowerVault 775N (Rackmount NAS Appliance) User Manual

Page 10

Advertising
background image

Table 1-7

provides the minimum requirements for the shared storage system(s).

Table 1-7. Cluster Shared Storage System Requirements

Hardware

Component

Minimum Requirement

Shared storage

system(s)

Up to four PowerVault 21xS or 22xS enclosures (for the shared disk resource) with the following

configuration:

Two SEMMs for each PowerVault 21xS

Two EMMs for each PowerVault 22xS

Redundant power supplies connected to separate power sources

At least two SCSI hard drives in each PowerVault 21xS or 22xS enclosure to support hardware-

based RAID functionality

Currently, MSCS supports only the Windows NT File System (NTFS) format for the shared storage

system.

Two volumes are the minimum requirement for an active/active cluster configuration (where the

active nodes process requests and provide failover for each other)

See "

Configuring Active and Passive Cluster Nodes

" for more information on active/active and

active/passive cluster configurations.

Two 1-, 4-, 8-, or 20-m SCSI cables for each PowerVault 21xS or 22xS storage system in the

cluster

Cluster Interconnects (Private Network)

Table 1-8

provides the minimum requirements for the cluster interconnects (private network).

Table 1-8. Cluster Interconnects (Private Network) Requirements

Hardware

Component

Minimum Requirement

Network

adapters

Any network adapter supported by the system for each cluster node. The network adapters for the private

network must be identical and supported by the system.

NOTE:

Dual-port Fast Ethernet network adapters are not recommended for simultaneous cluster connections

to the public and private networks. When you configure the network adapter in MSCS Setup to All

Communications, the public network can provide redundancy for node-to- node traffic in the case of a

failure in the private network segment.

Ethernet

switch

(optional)

One Ethernet switch for the private network (cluster interconnect).

Ethernet

cables

One standard or crossover Ethernet cable.

Standard Ethernet cable (not included with the Dell Cluster kit) connects two copper Gigabit Ethernet

(1000 BASE-T) network adapters.

Crossover Ethernet cable connects two fast 100 Mb/s Ethernet network adapters.

Ethernet

switch

cabling

(optional)

Additional Ethernet cables (not included) may be used to attached to an Ethernet switch for the public

network (client connections) and private network (cluster interconnect).