Console redirection screen, System security screen – Dell PowerEdge 2850 User Manual

Page 19

Advertising
background image

 

System Security Screen

Table 3

-5

lists the options and descriptions for the information fields that appear on the System Security screen.

 

Table 3-5. System Security Screen Options 

 

Console Redirection Screen

Table 3

-6

lists the options and descriptions for the information fields that appear on the Console Redirection screen. For more information about using

console redirection, see "

Using Console Redirection

."

 

Table 3-6. Console Redirection Screen Options 

 

Serial port 1 shares three usage models. For standard usage, serial port 1 attempts to use COM1 first, and then COM3. For BMC usage,
serial port 1 uses the COM1 address and communication can be either via the Serial port or the integrated shared NIC. RAC control uses
only the COM1 address.

 

NOTE:

Off and COM3 are not available options when Console Redirection is set to use Serial Port 1.

Speaker
(On default)

Sets the integrated speaker On or Off. A change to this option takes effect immediately (rebooting the system is not required).

 

Option

 

Description

System
Password

Displays the current status of your system's password security feature and allows you to assign and verify a new system password.

 

NOTE:

See "

Using the System Password

" for instructions on assigning a system password and using or changing an existing system

password.

Setup
Password

Restricts access to the System Setup program in the same way that you restrict access to your system using the system password feature.

 

NOTE:

See "

Using the Setup Password

" for instructions on assigning a setup password and using or changing an existing setup password.

Password
Status

Setting the Setup Password option to Enabled prevents the system password from being changed or disabled at system start-up.

To lock the system password, assign a setup password in the Setup Password option and then change the Password Status option to
Locked. In this state, you cannot change the system password using the System Password option and cannot be disabled at system start
up by pressing <Ctrl><Enter>.

To unlock the system password, enter the setup password in the Setup Password field and then change the Password Status option to
Unlocked. In this state, you can disable the system password at system start up by pressing <Ctrl><Enter> and then change the password
using the System Password option.

Power Button
(Enabled
default)

Turns system's power off and on.

l

 

If you turn off the system using the power button and the system is running an ACPI-compliant operating system, the system can

perform an orderly shutdown before power is turned off.

l

 

If the system is not running an ACPI-compliant operating system, power is turned off immediately after the power button is pressed.

The button is enabled in the System Setup program. When disabled, the button can only turn on system power.

NMI Button
(Disabled
default)

 

NOTICE:

Use the NMI button only if directed to do so by qualified support personnel or by the operating system's documentation. Pressing

this button halts the operating system and displays a diagnostic screen.

Sets the NMI feature Enabled or Disabled.

AC Power
Recovery
(Last default)

Determines how the system reacts when power is restored to the system. If system is set to Last, the system returns to the last power
state. On turns on the system after power is restored. When set to Off, the system remains off after power is restored.

 

Option

 

Description

Console Redirection
(Off default)

Sets the console redirection feature to Serial Port 1 or Off.

Failsafe Baud Rate
(11520 default)

Displays if the failsafe baud rate is used for console redirection.

Remote Terminal Type
(VT 100/VT 220 default)

Select either VT 100/VT 220 or ANSI.

Redirection After Boot
(Enabled default)

Enables or disables console redirection after your system restarts.