Dell Serial Attached SCSI 6iR Integrated and Adapter User Manual

Page 55

Advertising
background image

Troubleshooting

53

Integrated RAID

exception detected:

The BIOS detected an exception with one or more
RAID virtual disk. For additional troubleshooting
information, see the error message "

Volume

(xx:yy:zzz) is currently in state

“STATE”

.

Volume (xx:yy:zzz) is

currently in state

“STATE”

Lists the current state of the specified virtual disk
when it is not optimal. The state may include:

• INACTIVE: The virtual disk is inactive, possibly

foreign, or could be in any one of the states
mentioned below.

• DEGRADED: The virtual disk is in a degraded state

and has lost redundancy.

• RESYNCING: The virtual disk is degraded and

currently rebuilding.

• FAILED: The virtual disk has an error and is in a

failed state.

• MISSING: The virtual disk is no longer present

though a record of it remains.

Device not available

Device may not be ready at this time. The device will
be retried. If the problem persists, restart your
system.

Spinning up the

device!

The device currently being scanned is being spun up.

ERROR! Device is not

responding to Read

Capacity

The device did not respond to a read capacity
command. Contact Dell.

Failed to add device,

too many devices!

Could not allocate resources for additional devices.

ERROR! Adapter

Malfunctioning!

The adapter did not initialize properly. There may be
a problem with the adapter configuration. Reload the
BIOS configuration. Invoke the configuration utility
again and see if the issue persists.

MPT firmware fault

The LSI Logic MPT firmware faulted. Contact Dell.

Table 7-4.

BIOS Error Messages (continued)

Message

Meaning

book.book Page 53 Monday, September 15, 2008 2:47 PM

Advertising