Dell Serial Attached SCSI 6iR Integrated and Adapter User Manual

Page 56

Advertising
background image

54

Troubleshooting

Adapter removed from

boot order!

An controller that was previously in the boot order
was not found. It has either been removed from the
system or moved to a different slot.

Updating Adapter

List!

A new adapter was found for which there is no record.
A record will be created for it.

Adapter(s) disabled

by user

An adapter was found, but it has been disabled in the
Configuration Utility and will not be used by the
BIOS.

Adapter configuration

may have changed,

reconfiguration is

suggested!

A controller has been moved or reinstalled in the
system. Add it to the boot order using the available
resources.

Memory allocation

failed

The controller could not allocate enough memory to
load the Configuration Utility, its strings file, or its
options file. Reboot the system.

Invalid or corrupt

image

One of the images for the Configuration Utility, its
strings file, or its options file is corrupt. Reload the
BIOS. Reflash the firmware.

Image upload failed

Could not upload the image for the Configuration
Utility, its strings file, or its options file. Reload the
BIOS.Reflash the firmware.

Image not found

Could not locate the image for the Configuration
Utility, its strings file, or its options file.

Unable to load LSI

Configuration Utility

Could not load the Configuration Utility. This error
usually follows one of the four previous messages.

Unable to load LSI

Logic Corp MPT BIOS

MRT BIOS Fault 02h

encountered at

adapter PCI (XXh,

XXh,XXh)

Fusion-MPT Firmware

fault code 0706h

The controller was downgraded from the current
firmware revision to an earlier revision which cannot
support the current configuration information and
cannot be initialized. Contact Dell support for
assistance.

Table 7-4.

BIOS Error Messages (continued)

Message

Meaning

book.book Page 54 Monday, September 15, 2008 2:47 PM

Advertising