• Make the changes using the System Profile Custom selection.

• Set

System Profile in BIOS to Custom mode.

• Set

CPU Power Management to Maximum Performance mode.

• Set

Turbo Boost mode to Enabled.

You must enable DPAT with a controlledturbo command using one of the

following modes:

• Dell Remote Access Controller Admin (RACADM)
• Web Services for Management (WSMAN)
• Dell OpenManage Deployment Toolkit (DTK)

Enabling DPAT Using RACADM (Firmware RACADM: SSH or Telnet Session)

NOTE:

Ensure that LC and CSIOR are enabled before performing the configuration.

1 Set ControlledTurbo to Enable by running the following command:

$ racadm set bios.procsettings.controlledturbo

Enabled

2 Create commit and host reboot jobs by using the jobqueue command:

$ racadm jobqueue create BIOS.Setup.1-1 -r pwrcycle

-s TIME_NOW -e TIME_NA

3 Reboot the server and run CSIOR for the setting to take effect.

NOTE:

The BIOS settings only take effect after you reboot the server and run CSIOR.

Attribute value names are case sensitive.

Disabling DPAT Using RACADM (Firmware RACADM: SSH or Telnet

Session)

1 Set ControlledTurbo to Disable by running the following command:

$ racadm set bios.procsettings.controlledturbo

Disabled

2 Create commit and host reboot jobs by using the jobqueue command:

$ racadm jobqueue create BIOS.Setup.1-1 -r pwrcycle

-s TIME_NOW -e TIME_NA

3 Reboot the server and let CSIOR run for the setting to take effect.