Upgrading Your PowerVault NX1950 Integrated Solution

17

Upgrading Your
Dell™ PowerVault™ NX1950
Gateway Solution With the Latest
Solution Stack

To upgrade your Dell™ PowerVault™ NX1950 Gateway solution with the
latest solution stack, perform the following steps:

1 For the supported solution stack versions, revision numbers, and location

of all the components, see the

Dell PowerVault NX1950 Systems Support

Matrix located on the Dell Support website at support.dell.com.

2 Unassign any Logical Unit Numbers(LUNs) as some data may still be on

the LUNs and storage array.

3 On your Gateway solution, uninstall the existing EMC

®

solution stack in

the following order:

a

Virtual Disk Service (VDS)/Volume Shadow-Copy Service (VSS)

b

NaviCLI

c

NaviAgent

d

Navi Init wizard

e

EMC PowerPath

®

4.x.x

4 Restart your system.

NOTE:

You can also upgrade the Microsoft

®

Windows

®

Unified Data Storage

Server 2003 operating system from Standard to Enterprise Edition (optional).
For more information, see the Dell PowerVault NX1950 Systems Upgrading
Your Operating System

Guide that is shipped along with your upgrade kit.

Advertising