Activity LED

When the Activity LED is ON and the Fault LED is off, the drive is performing an operation. The Eject button should not be

pressed as the operation will be aborted, unless the application has disabled the Eject function during operation. If

aborted during a write operation, the written data may be incorrectly terminated resulting in errors if an attempt is made

to restore the data.

Clean LED

When the Clean LED is steady on, the drive is indicating that it needs cleaning by a cleaning cartridge. The Clean LED will

be turned on by:

100 hours of tape operation since last cleaning.

Media Management determined a suspect cleaning condition.

A fault situation where cleaning should be done to recover.

When the Clean LED is on, a cleaning cartridge should be run before any other tape activity is attempted.

Once lit, the Clean LED can only be turned off by running a cleaning cartridge. A power cycle will not clear the Clean LED.

Fault LED

If the Fault LED is lit, see

Troubleshooting

.

Tape Cartridge Operation

Use only certified quality cartridges for the PowerVault LTO-2-024 tape drives. Do not use worn or audibly noisy

cartridges. Cartridges which frequently require rewriting of large numbers of data-blocks per track should also be

discarded.

Loading a Data Cartridge

The cartridge must be inserted with the label facing up and the tape dust cover towards the LEDs as shown below. The

drive has a semi-soft loading mechanism: Slide the cartridge slowly into the drive until it stops firmly, then let go. The

cartridge will then move back a very short distance. The drive, once it has detected the cartridge, will lock the cartridge

and move it down into the drive mechanism. The tape threading will then take place and the motor sound may be heard.

Once a cartridge is detected by the Drive, the Activity LED will start flashing, and continue flashing until the tape is fully

threaded into the drive. With a brand-new tape, the drive will initialize the tape, spending some extra time until the

Activity LED is turned off.

To prevent damage to the drive or the cartridge:

DO NOT use excessive force

Ensure that you insert the cartridge in the correct orientation

Do not drop the drive or the cartridge (handle with care)

Figure 2: Cartridge insertion

Ejecting a Data Cartridge

The cartridge can be ejected either by pressing the Eject button located on the drive’s front panel, or by an Unload SCSI

command. The drive automatically rewinds and ejects the cartridge.

Notice: For the integrity of your backups and restores, do not press the Eject button when the Activity LED is

flashing.