A - level detection bleed valve (fig. 6), Fig. 7a, Fig. 6 fig. 7b – Chicago Pneumatic CPVS 40 User Manual

Page 12

Advertising
background image

Chicago Pneumatic Compressors

62 305 258 65

01/2008
Page 12

Section 5 - Options

A - Level detection bleed valve (Fig. 6)

1 - Description

The BEKOMAT type level detection bleed valve allows all air
consumption to be avoided while the compressor is not running.

2 - Option overview

- There is no air consumption due to the level detection system : an
inductive sensor detects the level of condensation and thus controls
the opening of the electric bleed valve. A low level of condensation is
also detected in order to close the electric bleed valve and to prevent
compressed air from being wasted.

- This type of purge valve does not require any maintenance. The
purge valve does not require the use of the metallic intake filter that is
usually installed on electronic purge valves to protect the solenoid
valve. The solenoid valve will not be damaged.

- Condensate treatment is made easier because it is not evacuated by
pressure, which enables easy separation of the water and oil stages.

1

2

3

4

5

6

1 - Condensation intake

4 - Main duct

2 - Capacitive sensor

5 - Electric valve

3 - Receiver

6 - Membrane

3 - Technical features

Maximum capacity of the compressor

: 706 cfm/min

Working pressure

: 11.6 / 232 PSI

Operating pressure

: 33.8 / + 140°F

Electric power supply

: 115V / 24V

AC socket in the compressor electric cabinet.

B -Advanced filtration to the compression

air inlet (Fig. 7a and 7b)

1 - Description

This system is equipped for "high efficiency" air filtration in order
to improve the quality of the air intake and to preserve the
compressor's oil and internal filter components.

This option is particularly useful in very dusty surroundings.

2 - Option overview

- This option is used as a replacement for the standard filter
- Certain atmospheric particles are smaller than 78

10-6

in, a limiting

threshold for traditional paper cartridge filters. The filter increases
filtration effectiveness by eliminating 99.97% of particles that
are larger than or equal to 118

10-6

in.

- The quality of the air intake by a compressor is essential. Low
quality air creates the following :
• Quick pollution of the oil thus an increase in draining cycles.
• Binding of the air / oil separator before 4000 hours thus an
increase in maintenance cycles and operation costs.
• Pollution increases the elements that filter into the air and oil,
speeding up the damage to the mechanical components of the
compressor, screw element,...
Filters in compliance with standard ISO 5011/2000.
- Exceptional filter longevity, from 18 months to 3 years of
continuous service (24 hours a day, 7 days a week), which is a
little more than 10,000 hours of operation of the compressor under
normal conditions.
- Installation of the filter(s), depending on the model, outside the
compressor, for intake of fresh air, hence resulting in a lower oil
temperature and more efficient compression (Fig. 7a and 7b).

x

y

Fig. 7a

1

2

3

4

5

6

Fig. 6

Fig. 7b

Cartridge

Air filter

Extraction duct

VORTEX pre-filter

x

y

CPVS 40-50-60

71 in

11.2 in

CPVS 75

71 in

13.6 in

Advertising