Section 7 - Maintenance

The maintenance period is limited to several essential operations. It
is strongly recommended that the power supply be cut off during
any adjustment or repair.

The summary on the CP instrument panel shows at a glance the
type and periodicity of operations to be carried out for the
compressor to function correctly.

Operations to be carried out

Daily

Every

Every

Every

Every

Every

Every

Every

500 hr

150 hr 2 000 hr (*) 4 000 hr

6 000 hr

8 000 hr

12 000 hr

Service A

Service B

Service C

Drain the condensates

Draining cock

X

from the cold oil circuit
(Section 8 - G)
Check and top up if

Oil level

X

necessary
(Section 8 - A)

Air filter

X

Replace the filter

Oil tank,

Oil change, oil refill

Oil change

X

X

with recommended oil
(Section 8 - A)

Control

Renovation of the

Suction housing

cleaning

Overhaul kit housing. Use the

lubrication

suction housing kit
Check the cleanliness of

Oil return pipe

Overhaul

the oil return pipe and

Kits the state of the seal

(Section 8 - F)
Change the part

Oil separator

X

according to the
instrument panel indication
(Section 8 - E)

Oil filter

X

X

Filter change

Oil radiator

Blowing of cooling

Final coolant

X

elements
Cleaning (Section 8 - D)

Control

Exchange the accessories

Valve at minimum

cleaning

Overhaul

supplied with the

pressure

lubrication

kits

maintenance kit
For motors fitted with

Motor for

grease, use

CPVS

X

Type ESSO

40-50-60-75

UNIREX N3 (0.53 ocs
per grease fitting)

Electric cabinet

X

X

Retighten power cable
connections.

Safety temperature

Check operation

test

X

(Section 8 - H)

NOTE : maintenance kits are available (see spare parts list).

(*) or at least every year

Parts

Observations

CAUTION

When the compressed air cools, part of the moisture sucked in by the compressor condenses. In order to protect the dryer against
the risk of an ice plug forming, it is essential to check regularly that the condensate drains are operating properly :
On the compressed air storage reservoir and on the filters :
• With a manual drain, drain regularly according to the moisture content of the ambient air.
• With an automatic drain, set the draining cycle accordingly and check that the drain is in good working condition.
This recommendation is also fundamental in a circuit comprising an absorption dryer (risk of saturation of the alumina).