To cancel the automatic calibration function, If "[a]" or "[g" on the tc-wa8esa and we805s or, Cal" on all other models flashes continuously – Sony TC-WR550Z User Manual

Page 11: Updating the calibration setting, Advanced recording operations, Iki f

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Advanced Recording Operations

Adjusting Bias and Recording

Level Calibration

Automatically

Since there are many different types of cassettes on the
market your tape deck automatically sets the
appropriate equalization characteristics and bias
current for each tape type (ATS: Automatic Tape
Selection). However, you can get better recording
results by doing the automatic bias current and the
recording level calibration. You can do automatic
calibration on either deck (TC-WA8ESA/WE805S only)
or only on deck B (on all other models).

^

DECK A/DECK B

<] / D>

o

foSn

1

Oi=iO I

Q

OP

№|C

iki

f

«

0(3

f~-r

—1

'—^

O

—r-

PAUSE ll<] / O PAUSE II

1

Insert the cassette you want to record on into
deck B or into either deck (TC-WA8ESA/WES05S

only).
Make sure the record-protect tabs on the cassette
have not been removed.

2

Press DECK A or DECK B on the TC-WA8ESA
and WE805S, or AUTO CAL on all other models
until "CAL" appears in the displav.

3

Press O or O to select the side of the tape to be

recorded.

To select

Press

The front side

The reverse side

<1

Press PAUSE II to start the automatic calibration
procedure.
The automatic calibration procedure starts (i.e.,

recording test tones, rewinding, and playing
back).
During the calibration, the counter changes from

9 to 0.

When the automatic calibration procedure ends,
the tape rewinds to the original position, the
counter returns to normal and the tape deck
stops.

5

Start the actual recording (see page 6).

To cancel the automatic calibration function

Press ■ on the deck you're using.

If "[A]" or "[g" on the TC-WA8ESA and WE805S or
"CAL" on all other models flashes continuously

The automatic calibration procedure has been interrupted
by:
— The end of the tape. Reverse the tape direction or rewind

the tape to a new position that allows recording of the
test tone.

— Damaged tape or dirty heads. Change the cassette or

clean and demagnetize the heads (see page 19).

Updating the calibration setting

If you insert a cassette and

"[

a

]

CAL" or "CAL

[g"

on

the TC-WA8ESA and WE805S or "CAL" on all other

models appears in the display, it means that automatic
calibration data in that deck for that tape type (I, II or
IV) exists. Howev'er, we recommend that you repeat

the automatic calibraion procedure each time you
insert a new cassette since cassettes of the same type
also vary in their characteristics.

Before recalibrating, be sure to turn off "E CAL" or
"CAL [g" on the TC-WA8ESA and WE805S or "CAL"

on all other models bv pressing DECK A or DECK B on
the TC-WA8ESA and WE805S or AUTO CAL on all
other models. Then start from Step 2 of the automatic
calibration procedure.

11

Advertising
This manual is related to the following products: