Trouble check 1

Symptom

Cause and/or Corrective Action

A vertical band appears when
shooting a very bright subject.

• The camcorder is not malfunctioning.

The playback picture is not
clear.

• EDIT is set to ON in the menu system.

-» Set it to OFF. (p. 31)

The picture is “noisy".

• The video heads may be dirty.

4 Clean the heads using the Sony V8-25CLH cleaning

cassette (not supplied), (p. 63)

The picture does not appear

in the viewfinder.

• The LCD panel is open.

Close the LCD panel, (p. 18)

• If VF PW-SAVE is set to ON, the picture disappears

automatically when you turn your face away from the
viewfinder (CCD-TRV72/TRV82 only).

Bring your face close to the viewfinder within 1/2 inch
(1 cm). Or set VF PW-SAVE to OFF. (p. 29)

The picture in the viewfinder
does not disappear even if VF

PW-SAVE is set to ON (CCD-
TRV72/TRV82 only).

• Sunlight or an incandescent lamp may prevent the

viewfinder sensor from working correctly. This is not a
malfunction.

An unknown picture is
displayed in the viewfinder or
on the LCD screen.

• If 10 minutes elapse after you set the POWER switch to

CAMERA without inserting a cassette, the camcorder
automatically starts the demonstration.

Insert the cassette and the demonstration stops.
You can deactivate the demonstration, (p. 30)

The picture does not appear
on the LCD screen.

• Incorporated fluorescent tube is worn out.

Please contact your nearest Sony dealer.

The five digit code appears.

• The self-diagnosis function is activated.

Check the code and solve the problem, (p. 72)

Others

Symptom

Cause and/or Corrective Action

The supplied Remote
Commander does not work.

• COMMANDER is set to OFF in the menu system.

Set it to ON. (p. 29)

• Something is blocking the infrared rays.

■> Remove the obstacle.

• The batteries are not inserted with the correct polarity.

■> Insert the batteries with the correct polarity, (p. 78)

• The batteries are dead.

4 Insert new ones. (p. 78)

There is dust in the
viewfinder (CCD-TRV62
only).

• Detach the eyecup and clean the viewfinder lens. (p. 64)

The picture from a TV or VCR
does not appear even when
the camcorder is connected to
outputs on the TV or VCR.

• DISPLAY is set to V-OUT/LCD in the menu system.

Set it to LCD. (p. 29)