GAS REQUIREMENTS AND INSTRUCTIONS

Following are important instructions and information concerning the requirements for the gas supply and service for

gas dryers. Warning: The gas supply and service for a gas dryer must comply with all local codes and
ordinances. In the absence of any local codes or ordinances in your area, the gas supply and service for your gas
dryer must comply with the latest edition of the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Failure to do so can
result in death, explosion, or ftre.

1. Gas supply requirements; Liquefied Petroleum

(L.P.) Gas (2,500 Btu/ft3 (93.1 MJ/m3)) service
must be provided at 10 + 1.5 in. water column

pressure,

2, Do not attempt to connect the dryer to Liquified

Petroleum (LP Gas) Gas service without a

qualified professional,

3, Isolate the dryer from the gas supply piping

system by closing its individual manual shut-off
valve during any pressure testing of the gas
supply system at test pressure equal to or less
than 2/1 psi (3.45 kPa).

4. Supply Line Requirements. Your laundry room

must have a rigid gas supply line to your dryer.
In the United States, an individual manual shutoff
valve MUST be installed within at least 6 feet
(1,8 m) of the dryer, in accordance with the
National Fuel Gas Code ANSI Z223.1. A 1/8 in.
N.PT, pipe plug must be installed as shown.

A

WARNING!

• DO NOT

attempt

any disassembly

of the

dryer. Any disassembly requires the

attention and

tools

of an authorized and

qualified service person or company,

• Failure to do so can result in death,

explosion, or fire.

5. If using a rigid pipe, the rigid pipe should be 1/2

inch IPS. If acceptable under local codes and

ordinances and when acceptable to your gas

supplier, 3/8 inch approved tubing may be used
where lengths are less than 20 feet (6.1 m).
Larger tubing should be used for lengths in

excess of 20 feet (6.1 m). It is also important that
you use pipe joint compound that is insoluble in

LP gas.

6. To reduce the danger of gas leaks, explosion, and

fire, please follow and observe the following

instructions and WARNINGS.

• Connect the dryer to the type of gas shown on the

nameplate,

• Use new flexible stainless steel connectors,

• Use Tefion tape and pipe joint compound

insoluble in LP gas on all pipe threads,

• Purge gas supply of air and sediment before

connecting the gas supply to the dryer in order to
prevent gas valve contamination. Before
tightening connection between gas supply and
dryer, purge remaining air until odor of gas is
identified,

• DO NOT use an open flame to inspect for gas

leaks; instead use a non-corrosive leak detection
fluid.

A

WARNINi

Use a new,

supply line

Install^Epwcfe^alve.

22

• Sea^dw«en all gas connections.

• If

gas pt€

water columiW

• Examples of a quaj^i^

id heating |

com^yt^ersgiBOS
peigg

• Failur^^^!^ can result in death,

^

explom!iBpK.^efr>.

*

R^d gas

adi

cei