CHAPTER 3: INSTALLATION

3-4

EMM-E6 User’s Guide

Switch definitions are as follows:

• Switch 1 - Cabletron Systems use only.

• Switch 2 - Cabletron Systems use only.

• Switch 3 - For manufacturing use only. Keep in

OFF

position.

• Switch 4 - MIMREV (Management Interface Module Revision).

This switch remains in the

OFF

position for normal operation. Only

if you are using THN-MIM part numbers 9000043-05 and below in
your MMAC-FNB should the switch be in the ON position.

• Switch 5 - Baud Rate Default. Allows you to set the Console port’s

baud rate. The OFF position sets the baud rate to 9600. The ON
position sets the baud rate to 2400.

•

Switch 6 - Forced Download. Changing the state of this switch

(i.e., moving the switch from one position to another) clears
download information from NVRAM and forces the EMM-E6 to
download an image file from the station acting as the EMM-E6’s
BOOTP server.

Changes to switch positions only activate their associated
functions after the EMM-E6 is reset.

NOTE

Do NOT change the state of Switch 6 unless you:

-

have a station acting as a BOOTP server, and

that station contains the EMM-E6 image file.

-

intend to set up a station to act as a BOOTP

server for the EMM-E6.

NOTE