Exposure control Aperture-priority automatic

exposure with manual override

and backup mechanical control;

through-the-lens, full aperture

metering via silicon photo diode

(SPD) with center-weighted

metering pattern and metering

circuits incorporated into

camera body; meter works with

all viewfinders

ASA 12 to ASA 6400

EV 1 to EV 18 at ASA 100 with

f/1.4 lens

Provided; ±2 EV in one-third

increments

Provided; operates on Auto to

electronically lock in shutter

speed

Provided; special Nikon type

located at base of rewind knob;

accepts Nikon SB-12 shoe­

mounting electronic flash unit or

TTL connecting cord from SB-11

for TTL direct flash output

control using camera's SPD

metering cell

Flash synchronization Speeds up to 1/80 sec. with

electronic flash; with SB-12, flash

sync is automatically set to 1/80

sec. when shutter speed dial is

set at "A," or 1/125 sec. or above;

flash synchronizes with shutter

speed set at slower shutter speed

settings; threaded sync terminal

Film speed range

Metering range

Exposure

compensation dial

Exposure memory

lock

Accessory shoe