Arc Machines 415 WDR User Manual

Page 12

Advertising
background image



Model 415
Operation Manual

Document No. 740084

Revision N

7

2.

INPUT POWER, DETAIL - The M-415 can have 1 of 3 operating ranges:

Voltage

Phase - Freq.

Max Input Current

Required

Transformer Type

Model 415

Main Circuit Breaker

200 VAC

3 - 50/60 Hz

50 amperes Service

Universal

60 Ampere-600 VAC

240 VAC

3 - 50/60 Hz

45 amperes Service

60 Ampere-600 VAC

400 VAC

3 - 50/60 Hz

25 amperes Service

60 Ampere-600 VAC

440 VAC

3 - 50/60 Hz

25 amperes Service

60 Ampere-600 VAC

480 VAC

3 - 50/60 Hz

20 amperes Service

60 Ampere-600 VAC

575 VAC

3 - 50/60 Hz

20 amperes Service

60 Ampere-600 VAC

FOR POWER SUPPLIES MADE BEFORE JANUARY 1999

200 VAC

3 - 50/60 Hz

60 amperes Service

International

60 Ampere-415 VAC

220 VAC

3 - 50/60 Hz

60 amperes Service

60 Ampere-415 VAC

380 VAC

3 - 50/60 Hz

40 amperes Service

60 Ampere-415 VAC

415 VAC

3 - 50/60 Hz

40 amperes Service

60 Ampere-415 VAC

FOR POWER SUPPLIES MADE BEFORE JANUARY 1999

230 VAC

3 - 50/60 Hz

50 amperes Service

Domestic USA

50 Ampere-600 VAC

240 VAC

3 - 50/60 Hz

40 amperes Service

50 Ampere-600 VAC

440 VAC

3 - 50/60 Hz

40 amperes Service

50 Ampere-600 VAC

480 VAC

3 - 50/60 Hz

40 amperes Service

50 Ampere-600 VAC

3. OUTPUT POWER - Straight polarity, constant current DC regulation intended for GTAW

welding

only.

Minimum current Output all cases .................... = 5 Amperes DC
Maximum current Output ................................. = 400 Amperes DC continuous or peak pulse

4.

CIRCUIT BREAKER – Also used as ON/OFF switch, is a 60 Amp 3 phase Auto-Trip, with
electrical Emergency Stop function available on the Power Supply, Operators Pendant and
from an Optional External Hard Wire Command.

5.

POWER CABLE -25 foot (7.6 m) Neoprene jacketed harmonized CE approved 4 conductor 8
AWG (10mm²) cordage, rated voltage: 500V.

6.

STANDARDS - The M-415 is designed and maintained to meet all applicable IEC and ISO

standards as well as all applicable EC Directives.

7.

RATED CONDITIONS - The system will meet or exceed the functional ranges and

tolerances stated, provided that the following conditions exist:

1.

Input Voltage does not deviate greater than +/- 10% from normal voltage.

2.

Ambient operating temperature range is between 0 degree C (32° F) and 40° C (105° F)

3.

Arc Voltage at the power supply terminals is equal to or less than 30 volts.

4.

All electrical performance is based on maximum weld head distance of 200 feet (61 m)

from

the

M-415


2.1

PHYSICAL CONSTRUCTION


1.

Cabinet material - aluminum and steel

2.

Dimensions (basic Power Supply):

Height: 39 inches (990.6 mm)

Width: 26 inches (660.4 mm)

Depth: 36 inches (914.4 mm)

3.

Weight: Less than 700 lb. (317.5 kg) depending on configuration