Warning – Arc Machines 415 WDR User Manual

Page 45

Advertising
background image



Model 415
Operation Manual

7.

At this time you should also decide whether or not everyone should logon or if you

want to allow a certain level of access without logon. As the system was supplied from

the factory no logon is required and everyone can have "Supervisor" Level of security.


8.

If you wish to change this, from the M415 Security Administration dialogue box select

"Advanced". A log on required check box and two default logon radio buttons will

appear. Selecting Logon Required will require everyone to have a logon and password

just to operate the system. If you do not want everyone to logon then select the level

(supervisor or operator) that they will have without logon.

5.12

PROJECT DATA RECORDING


The M-415 has the ability to record the following information and automatically print out this

information, along with the weld parameters used, at the end of each weld sequence:


1.

Weld Head Model Number used.

2.

Weld Head Serial Number used.

3.

Weld Name or ID number.

4.

Power Supply Serial Number used.

5.

Note

field

6.

Date and Time of Printout

7.

Date and Time of Weld Pass Sequence in WELD mode.

Items 1, 2, 3, 4 and 5 must be supplied by the user. To enter this information touch the control

panel icon (farthest right on tool bar) and then touch PROJECT DATA.


5.13 GENERAL

MAINTENANCE

NOTE

Calibration of the entire M-415 system is contained in the calibration section of the M-415

Maintenance Manual. Weld Head Travel and Wire Feed Calibration is contained in steps

5.10 and 5.11 of this section.

WARNING

Always disconnect the AC power cable from the line voltage before attempting any repairs to this

welding power supply.


1.

AIR FILTERS - The M-415 power supply has two (2) foam air filters behind a single screen in

the front of the power supply. Inspect these air filters regularly. To inspect, remove the

two captive screws at the top of the screen and tilt the screen forward to expose the filters.

The foam filters may be removed, washed in water and detergent, dried and reused or

replaced. Do not operate unit without filters in place.


2.

COOLANT - The coolant tank in the M-415 holds approximately 2.5 gallons. Check coolant

level periodically. Using different weld heads will remove coolant from the tank over a period

of time. Fill the tank per instructions of section 3.

3. Cleaning exterior and interior surfaces - Prolonged use in a dusty shop or outside

environments may cause the outside surfaces to accumulate a coating of dirt and dust. Do

not use shop air (usually too wet) to blow dust particles away from panels. Either wipe it off

with a damp cloth or use a vacuum cleaner with a soft brush . Where a vacuum brush

cannot reach, use clean, soft paint brush and then vacuum.