5.10

WELD HEAD WIRE FEED CALIBRATION

NOTE

Once a weld head has had its Wire Feed and Travel Tachometers calibrated to an M-415 it can

be moved from one M-415 to another M-415 without needing to be re-calibrated. However, if the

motor assemblies have been repaired, replaced or calibrated to a different Model Power Supply

(M-227, M-215) they may need to be re-calibrated. If in doubt they should always be checked to

insure that they are calibrated. To check the Wire Feed calibration of a Weld Head perform the

following

steps:


1.

Insure that the weld head is connected per section III and the Weld Head manual. Wire Feed

calibration is done by feeding the wire and measuring actual speed. Before proceeding

CHECK THAT THE HEAD IS FREE TO FEED WIRE SAFELY


2.

To manually calibrate the user will need to have a Weld Schedule in the Library programmed

in accordance to the Calibration Procedure contained in the operation manual for the

particular Weld Head being used


3. A Wire Feed calibration schedule will always be run in TEST Mode and usually contains the

following:


Onelevel Functions

Prepurge

000

Level Advance

Time 1.0

Upslope

00.0

Start Mode

RF

Wirefeed Start Delay 00.0

Wirefeed Retract

0.0

Travel Start Delay 00.0

Travel Direction

CCW

Postpurge

000

Downslope

00.0

Wirefeed Stop Delay 00

Travel Stop Delay

00

Multilevel Functions

Level Time

60

Pri Travel

0.0

Pri Amps

000

Travel Step

CONT

Pri Wirefeed

100 (IPM)

Pulse Mode

OFF

NOTE

Insure that all other programmable functions are not active or used during calibration.

INSURE THAT THE WELD/TEST MODE IS IN TEST


4.

Level 1 Time needs to be set for 60 seconds (1 minute). Pulse Mode should be OFF so only

one Wire Feed Speed is checked (primary). The Wire Feed Primary IPM on most weld

Heads should be set to 50 or 100 IPM or equivalent meters (or a rate closer to actual weld

schedules being used) . Insure that the Wire Mode switch is set to ON.


Note that no Start Delays or Stop Delays are used. It is very important for calibration that the

wire start feeding at the beginning of the of the Level 1 Time and stop at the end of

the Level 1 Time.

5. Create or recall from the LIBRARY the appropriate Weld Schedule and connect the Weld

Head to be calibrated. Insure that the system is SAFE to feed wire and that the System

Mode is in TEST.

6.

Jog the wire until it is at the end of the nozzle but not protruding.

7.

Press Sequence Start. Wire should feed for 60 seconds. When Sequence is over cut the

wire flush with the nozzle and measure. It should be whatever value was programmed. If it is

not adjust the Wire Feed Cal Potentiometer on the Weld Head. Repeat step 6 and 7 until the

wire is calibrated.