Figure 2: application register diameters – B&M 77101 STARTER, FORD, 3/8 DEPTH FLYWHEEL, 289, 302, 351W, 164 T MANUAL User Manual

Page 2

Advertising
background image

2

INSTALLATION

STEP 1. Disconnect the battery
cables, removing the negative cable
first.
STEP 2. Remove the old starter,
and make sure the mounting flange
is clean and burr free.

STEP 3. Install the StarTek starter.
Leave all shims out at this time.

STEP 4. With the starter now in
position, make sure the solenoid
housing has maximum clearance
from

heat

sources

and

other

components. The starter can be
clocked in four different locations on
the mounting block to obtain the
best position. To re-clock the starter,
first remove the starter, then remove
the three M6 x 1 mounting bolts
between

the

starter

and

the

mounting block and re-position
accordingly. Re-Torque to 8 ft-lbs.
Please see Figure 3.

STEP 5-1. (Pinion Engagement):
There are two possible methods to
measure pinion engagement. The
First (Preferred) Method:
With the
starter removed, manually extend
the pinion and measure the distance
from the outer surface of the pinion
to the starter mounting flange where
it bolts to the bellhousing. Record
this

as

dimension

“A”.

Then

measure from the bellhousing /
block plate to the face of the ring
gear. Record this as dimension “B” –
this dimension should be close to
3/8” or 3/4”, depending on your
application. Please see Figure 4. A-
B needs to be between 1/4” to 3/8”.
If A-B> 3/8”, then remove the
mounting block and install the shim
ring and outer shim. (Please see
Figure 5.) This will move the pinion
away

from

the

ring

gear

approximately .060”, or 1/16”. If A-B
is significantly out of range, most
likely the wrong application starter is
being used.

STEP 5-2. (Pinion Engagement):
The Second Method: This method
is NOT preferred. Steps 6-10 must
be

complete

before

this

procedure

is

performed.

Performing this procedure will

Ring Gear

Tooth #

Transmission

Starter

Register

Diameter

Depth

Starter

164

4 Spd

4.130”

3/8”

77101

164

Automatic

4.084

3/4”

77100

157

4 Spd & Auto

4.084

3/4”

77100

Figure 3: Starter Clocking Positions

Table 1: Application Reference Chart

Figure 2: Application Register Diameters

Advertising