6 function set, Function set – Salter Brecknell LPS-15 User Manual

Page 16

Advertising
background image

14

LPS Series User Instructions

SP.3

The scale will transmit the following data once the reading becomes stable
and will not allow a second print until the scale reading returns back to
gross zero:

Gross 123.8 kg Net 120.4 kg Tare 3.4 kg

4.

Use the HOLD and UNITS keys to change the value of X. When you are done
making changes press the TARE key to accept the changes and go to next
step (hold function). . .

Hld.xx is displayed. This means you are in Hold function setting mode.
xx values 00,01,02,03…99

Hld.00 = hold function mode 0

Hld.01 = hold function mode 1

Hld.02 . . .99 = hold function mode 2-99

5.

Use the HOLD and UNITS keys to change the value of each xx. When you are
done making changes press the TARE key to accept the changes and restart
the scale.

On any step in this section you can press the ZERO key to exit the setting mode.

3.6 Function Set

1.

When the scale is in normal weighing mode, press and hold the HOLD key and
then press down and hold the ON/OFF key until. . .

F-Set is temporarily displayed, then FS. oN or FS.oFF is shown. If the
Function Set is enabled you are allowed to modify the calibration unit of
measure, display divisions (n), the division size (d) and location of the
decimal (dot) during calibration. If you choose OFF, these are not
available during calibration.

2.

Press the UNITS key to toggle between oN or oFF. Press the TARE key to
save the displayed choice. . .

tr. oN or tr. oFF is displayed. This stands for AZT (auto zero tracking).
Choose ON to enable AZT and OFF to disable AZT.

3.

Press the UNITS key to toggle between oN or oFF. Press the TARE key to
save the displayed choice. Factory default is ON. . .

Indicator exits the Function Set mode.

4.

Press ON/OFF anytime while in the Function Set mode to exit this mode.

Advertising