Salter Brecknell 7840 User Manual
Page 19

Model 7800 Family Weight Classifiers User’s Manual
19
27. Press the TEST key...
The current unit-of-measure LBS (for
pounds) or 1000G (for kilograms), is
displayed.
28. Press the ZERO key...
PRTOUT is displayed. This stands for
output print format.
29. Press the TEST key...
The current output print format is dis-
played. See Table 3 for details.
30. Pres the ZERO key. . .
LOC-GR is displayed. This stands for
local gravity.
31. Press the TEST key. . .
The current local gravity setting is
displayed.
32. Press the ZERO key . . .
CAL-GR is displayed. This stands for
calibration gravity.
33. Press the TEST key. . .
The current calibration gravity settings is
displayed.
34. When you are finished, press the ZERO key,
until DONE is displayed, then press the
TEST key to return to the top menu level...
DIAG is displayed.
Or close Switch 1 to return to normal weigh-
ing mode.