3 causes and rectification of faults – CASO Germany MCDG 25 master User Manual

Page 65

Advertising
background image

caso MCDG 25 Master (black)

65

Error code Description

E01

Excessive temperature within cooking chamber

The overheating cut-out terminated the current program at a cooking
chamber temperature of 250 °C.

Press the Stop button to acknowledge this fault.

The device can be re-activated after the cool down phase.

E02

Low temperature protection
When the system enters into super low temperature protection status, the digital
display shows “E02” and continues to beep till the system comes back to normal
condition and then press “Stop”.

E03

Sensor fault

The device has detected an error on a sensor and has terminated the
current programme.

Press the Stop button to acknowledge this fault.

Please note

► If error messages continue to appear after an extended waiting period and restarting

the device, then the device will need to be sent to Customer Service to be inspected.

15.3 Causes and rectification of faults

The following table assists in localizing and rectifying minor faults.

Error

Possible cause

Action

The selected program will
not start.

Device door is not closed

Close device door

Power plug is not
plugged in

Plug in mains plug!

Fuse is not activated

Activate fuse

The turntable turns jerkily.

Dirt between the turntable
and the base of cooking
camber

Remove dirt

Dirt on rolling ring

Cooking vessel too large

Use different cooking vessel

Food is not sufficiently
defrosted, warmed up or
cooked after preset time
has elapsed.

Incorrectly selected time
or power level

Re-set time and power level

Repeat process

The device functions but
the cooking chamber
lighting does not work.

Defective cooking
chamber light.

Have Service dept repair
cooking chamber light.

Advertising