Vintage Cellars CP:LATK-VS-R User Manual

Vintage Cellars Equipment

Advertising
background image

VS Low Ambient Fan Cycling Control Installation Instructions.doc

Released: 11/14/12

Revised: 11/14/12

Page 1 of 4

VS Low Ambient Fan Cycling Control Installation Instructions

1.

Low Ambient Fan Cycling Control wire identification:

2.

Disconnect all power from unit.

3.

The unit housing is assembled using #2 Phillips head screws.

4.

For units with a front grill: remove screws holding front grill. Pull the selector knob off of the fan
speed control and remove the grill.

5.

For units with a front duct hood kit, remove both top and bottom duct hoods.

6.

Remove wall mounting brackets and outdoor cover if applicable.

7.

Remove top cover. Lift the cover up to remove from unit.

8.

Remove all foil tape blue insulating foam from the condenser side (rear half) of the unit.

9.

Locate the discharge line 1/4" access valve and remove the threaded cap.

10. Install the Fan Cycling Control as shown:

11. See following pages for detailed wiring instructions.
12. When wiring is complete and control function is verified, replace all insulating foam and seal all

seams with foil tape.

13. Replace housing sheet metal and put unit into service.

Fork terminal for connection to terminal block #4

Splice connector to crimp to
condenser fan "Blue" wire

Fan Cycling Control
with female flare fitting

Attach control to 1/4" male
service valve fitting using two
flare wrenches. The bottom
wrench is required to prevent the
access valve from twisting, and
the top wrench tightens the
control flare to the access valve.

Discharge line
1/4" access
valve on
condenser side
of unit.
Discharge line
routes from
compressor to
top of
condenser coil.

Advertising