Step #1 install glazing materials – EFCO 5800 Series User Manual
Page 13

PROJECT SHOP DRAWINGS.
BLOCK EVEN WITH THE
FRONT OF THE MULLION
POSITION THE SETTING
TONGUE.
9/2000
bite should be 9/16" in a 2 1/2" wide system. Push the infill completely
back against the interior gaskets.
POSITION THE ANTIWALK
OF THE VERTICAL GLASS
OPENING. SILICONE THE
INSTALLED.
AFTER THE GLASS IS
BLOCK INTO POSITION
BLOCK AT THE CENTER
THE HORIZONTAL SETTING BLOCKS
MUST BE POSITIONED AT 1/4
POINTS OR AS SPECIFIED IN THE
Verify that all gasket retainer pockets are free from dirt and foreign
matter. Place the specified setting blocks and antiwalk blocks as shown in
the approved project shop drawings. Set the specified glazing infill into
the corresponding opening, ensuring positive bearing on the setting blocks
and an equal glass bite at all sides of the infill panel. The typical glass
SECTION VII: GLAZING INSTALLATION
STEP #1 INSTALL GLAZING MATERIALS
PAGE 11