EFCO 5XPT Series User Manual

Page 26

Advertising
background image

EFCO CORPORATION 6/8/2012 PART NO. YW44

Page 26 of 34

5XPT SLIDING GLASS DOOR INSTALLATION INSTRUCTIONS























See Fig. 8 for Steps A and B below (operable jamb to threshold):
Step A. The full length sealant across the sill at the threshold will need to wraparound the
weather-strip leg to the jamb.
Step B. Marry a vertical seal to the sealant across the sill and seal the joint between the weather-strip

leg and threshold. This seal joint will follow the underneath profile of the threshold and fill the
gap between both the horizontal and vertical weather-strip. All sealant joints must be
continuous with one another and tooled with no voids.


See Fig. 9 for Steps C and D below (fixed jamb to fixed panel):
Step C. The full length sealant across the sill at the fixed panel will need to wraparound the weather-

strip leg to the jamb.

Step D. Marry the full length sealant up the jamb with the sealant across the sill. This sealant will

marry with the sealant at the head. All sealant joints must be continuous with one another
and tooled with no
voids.



















All sealant must be continuous with
one another and tooled with no
voids.

All sealant must be continuous with
one another and tooled with no voids.

FIXED
PANEL

FIXED
JAMB

JAMB

SILL

SILL

THRESHOLD

Full length sealant up jamb

Full length sealant across sill

Full length sealant across sill

Fig. 8

Fig. 9

Weather-strip leg

Weather-strip Leg

Advertising