Suggested test setup diagram – ETS-Lindgren 3303 Monopole Antennas User Manual

Page 22

Advertising
background image

5.

Establish a reference level by decreasing the attenuation level until the

signal can be detected by the receiver. Note the attenuator setting.

6.

Relocate antennas so that the screen room wall is between them.

7.

Reduce attenuation further until signal is again seen at the same level

as without shielding.

The difference in the two attenuator settings is the shielding effectiveness. If the

signal cannot be seen with a zero setting, then the shielding effectiveness is

greater than the attenuation range or the power amplifier does not have enough

power. Suggested Test Setup Diagram on page 22.

The table on page 24 shows the maximum shielding effectiveness measuring

capability of the Model 3305 E-Field Shielding Effectiveness Test Kit and the

approximate wattage required for the Model 3303 Rod Antenna to meet the

minimum shielding requirements of NSA 65-6.

These shielding effectiveness readings are valid only if the power

amplifier is operating in the linear region. This can be verified by

reducing (or increasing) attenuation and observing the receiver signal

on the analyzer or receiver. If the receiving signal also decreases (or

increases) by the same amount then the amplifier is operating in the

linear region.

Suggested Test Setup Diagram

See next page for diagram.

22

|

Model 3305 Suggested Test Setup

Advertising