11
3.0 Specifications
Electrical Specifications
Frequency Range:
100 kHz
–65 MHz
Lines plus Ground:
2
Maximum Load Capacity:
25 A
This rating may be increased to
30 A provided that the duty cycle is
reduced to 20%.
Maximum Voltage
Line-to-Ground:
220 VAC
Maximum line-to-line voltage must
not exceed 220 volts AC RMS.
Line-to-Line:
400 VAC
Maximum line-to-ground voltage
must not exceed 440 volts AC RMS.
Network Inductance:
5 µH / 50
Ω
Power Source Frequency:
DC
– 400 Hz
Environmental
Installation:
Indoor use only
Altitude:
15000 ft (4572 m) max
Temperature:
0
°
C to 40
°
C (32
°
F to 104
°
F)
Relative Humidity:
80% up to 31
°
C (87.8
°
F)
decreasing linearly to 50% at
40
°
C (104
°
F)