Installation
| 15
• The input power connection to
the line side of the Model 3850/2
is made through the red and
black pin receptacles labeled L1
and L2 on the back panel.
Power to the Model 3850/2
should be through a properly
rated circuit breaker and/or a
switch which can remove power
from the unit in case of
emergency. This device should
be installed near the
Model 3850/2.
• The green pin receptacle and
the brass lug terminal are both
connected to chassis ground.
Prior to energizing the
Model 3850/2, the earth
connection from the power
mains must be connected to the
green pin receptacle.
• The brass lug terminal should be bonded to the ground plane of the
conducted emissions test setup. This line does not provide high frequency
isolation and should not carry any voltage above earth potential.