| Application

Application Note: Voltage-Selectable Battery Charger

Part Number:

102615, Rev A

Date:

May 25, 1993

B

ATTERY

C

HARGER

O

PERATION

The ETS-Lindgren voltage-selectable battery charger is solely intended for

charging the sealed lead-acid batteries found in ETS-Lindgren products. The

battery charger is a means of providing the necessary charge voltage and current

from either a 115 VAC 50/60 Hz or 230 VAC 50/60 Hz source.

It is necessary to select the proper input voltage prior to connecting

the battery charger to the power mains. The voltage select switch is

located adjacent to the power input receptacle.

To maintain safety requirements, use the CSA-certified power cord provided. If it

is necessary to provide other means of attaching the battery charger to the power

mains, it is required that a Type HD 21 (PVC cord) or Type HD 22 (rubber cord)

with a nominal cross-section of 0.75 mm

2

be used.

The battery charger provides both fast and trickle charge operation. Switching

from one charge mode to the other is provided automatically by the charger. The

front panel indicator marked FAST CHARGE illuminates when the battery

charger is in the fast charge mode. When the POWER ON light is illuminated and

the FAST CHARGE light is extinguished, the battery charger is in the trickle

charge mode.

Always remove mains power before opening

the housing.

The battery charger is protected against overcurrent by a 200 mA 250 VAC

time-delay fuse. If it becomes necessary to replace the fuse, use a fuse of the

same type and rating to maintain safe operation. The fuse is accessible by

removing the two Phillips head screws on the underside of the unit. The output of

the battery charger is protected against overcurrent conditions by use of

fold-back circuitry.