The Model 4610 Royce Field Site Source generates a 10 MHz fundamental

frequency and harmonics at 10 MHz increments up to 600 MHz. A rod antenna is

provided which should be connected to the Type N connector located on the top

of the unit. This Type N output can also be connected to a spectrum analyzer to

verify performance of the unit.

Power to the Model 4610 is provided by rechargeable sealed lead-acid batteries

(two are provided at six volts DC each). In the detented position of the power

switch, power is provided to the unit and a power on indicator should be

illuminated. When battery voltage discharges to a predetermined minimum level,

a low battery indicator will illuminate (should the batteries experience a deep

discharge, neither light will be illuminated). At this point, the power switch should

be placed in the Off/Charge position and batteries charged using the

charger port located adjacent to the power switch. Charging can be made with

either the 100 VAC/60 Hz charger or the optional 220 VAC/50 Hz charger.