TRANSMISSION OIL TEMPERATURE GAUGE AND
SENSOR INSTALLATION INSTRUCTIONS

Models: R43566 R43599 R52566 R52599 R53566 R53599 R59566

R59599 R68566 R68599 R69566 R69599 R82566 R82599

1



Disconnect batteries. Do not reconnect battery power until system is

fully configured to avoid risk of shock or fire.

I C O N K E Y

CAUTION

Tools may be required

Shown in picture

2

Install Electronic Signal Processor (ESP) and ESP harness according to

instructions.

3



Connect the Temperature Sensor Harness to the ESP Harness as follows:

a. Remove plugs from cavities 10 and 11 of connector A (gray) of the ESP.

b. Using a pair of needle nose pliers, pull the orange wedge lock out of connector A.

c. Insert the terminal from the black wire (thermistor ground) into cavity 11 of connector A on

the ESP, pushing until it snaps into connector A.

d. Insert the terminal from the white wire (thermistor signal) into cavity 10 of connector A on the

ESP, pushing it until it snaps in place.

e. Note: Terminals will be close to flush with the top of the connector when fully seated.

f. A firm pull of the wire will confirm whether they are properly seated.
g. Push the orange wedge lock back into position. If any of the wires are not fully seated, the

wedge lock will not insert into position.

h. Reconnect connector A (gray) to the ESP.

Figure 1: Connector A top and bottom
view. Shown with plugs and wedge lock

installed. Wires pre-installed in holes 1

through 7 and 12 are not shown.

Figure 2: Remove plugs and wedge lock as
shown. Wedge lock is replaced once wires are

positioned properly.