How to operate – Just Better LD-5000 Prowler Leak Detector User Manual

Page 3

Advertising
background image

HOW TO OPERATE

1) TURN ON: Press the ON/OFF button once to turn on and again to turn
off. NOTE: Hold button down for approximately 1 second to turn unit off.

2) WARM UP: The detector automatically energizes the sensor condi-
tioning it for use. During the sensor conditioning cycle, the digital graph
leak size indicator wil gradually increase and the detector will sound a
slow “beep”. Warm up mode is usually less than 20 seconds and is com-
plete when the digital graph displays all 10 bars. NOTE: When the de-
tector has not been used for long periods, conditioning may take slightly
longer than usual.

3) READY: The detector is ready to begin searching for leaks when the
sensitivity setting (Hi, Med, or Low) and the battery indicator are displayed
on the LCD. The audio “beep” increases in frequency.

NEED A PICTURE of Control Panel

LOW BATTERY INDICATOR

The battery indicator consists of the battery outline with 3 bars within the
outline and located in the upper center portion of the LCD display. Bat-
tery level indication is the following:

Three Bars:

Full Voltage

Two Bars:

1/2 Life

One Bar:

1/4 Life

No Bars:

Low Voltage (Change Batteries)

No Bars/ Blinking:

Unit will be disabled and not function properly

in

this

state

Replace the 4 AA Alkaline batteries when the battery indicator shows no
bars. Follow battery installation instructions under MAINTENANCE.

POWER ON/OFF

BACKLIGHT BUTTON

MUTE BUTTON

SENSITIVITY

LEVEL

Advertising