Directions For Use

C

A

B

D

E

EVAPORATOR

COMPRESSOR

CONDENSER

RECEIVER

MANIFOLD

COMPRESSOR

A

B

C

D

E

Charging and

Discharge

Suction

Low Side

High Side

Evacuation Port

Service Valve

Service Valve

Blue

Red

Yellow

Red

Blue


To Observe

Closed

Closed

Back Seated

Back Seated &

Operating Pressures

& Cracked Open

Cracked Open

To Charge Refrigerant

Open

Closed

Connect Line

Back Seated

Front Seated

Through Suction Valve

to Refrigerant Supply

& Cracked Open

To Charge Oil

Open

Closed

Connect Line

Back Seated

Front Seated

Through Suction Valve

To Oil Supply

To Charge Liquid Refrigerant

Closed

Open

Connect Line

Midway Open

Through Discharge Valve

To Refrigerant

To Build Low Pressure;

Open

Open

Refrigerant

Back Seated

Midway Open

For Control Setting

Line Closed

& Cracked Open

Or Leak Detecting
To Purge Refrigerant

Closed

Open

Refrigerant

Back Seated

From Discharge Valve

Line Open

& Cracked Open

To Evacuate With

Open

Open

Connect To

Midway Open

Midway Open

Auxiliary Vacuum Pump

Vacuum Pump

Caution: Always consult

equipment manufacturer's

service manual or instruc-

tion sheet for recommended

procedures.

FOR PROFESSIONAL USE ONLY

JB manifolds are designed for use by technically trained

AC/R service engineers only. Due to the high pressures encoun-

tered in all systems that this manifold will be used on, plus the

dangers due to the physical and chemical nature of refrigerants

and oils present in all systems, misapplication could result in

injury or death.

LIMITED WARRANTY

Manifold bar has a lifetime warranty, while the components, i.e.

gauges, hoses, handles, hose holders, etc. are covered under

the limited warranty policy. Products are warranted for a period

of one year from date of shipment by JB and limited to repair,

replacement or credit, if in our opinion are defective due to

workmanship and/or materials. Defective components should be

returned to the wholesaler from which the product was pur-

chased for evaluation.
Manifolds are designed for use with all refrigerants except

ammonia (R-717). Working pressures are limited to gauge dial

range. Use of this manifold under any other conditions voids the

warranty.