RS485 Termination Jumpers

The CP-RIO3-46-OPT offers onboard one 120 ohm termination resistor per channel which can
be used to terminate the differential line pairs in case the serial channel is a beginning or end
node of a RS485 two-wire network.

19

TRxD+

3

3

44

TRxD-

8

20

45

21

1

46

6

22

47

23

7

48

4

24

GND

5

49

2

25

50

Table 5-6: Termination Jumper Settings for CP-RIO3-46-OPT

CHANNEL

SETTING

DESCRIPTION

0

1

2

3

J1

J3

J5

J7

Open

(default)

No 120 ohm termination

Set

120 ohm termination between the differential lines
Termination between TRXD± in half duplex mode.

Table 5-5: Pinouts of Front Panel Adapter Connectors (Sheet 2 of 2)