19

Parallel Port Interface

MOPSlcdLX User's Guide

10 Parallel Port Interface

The MOPSlcdLX incorporates a parallel port that can be set to uni-/bidirectional and supports EPP operating
modes.

10.1 Connector

The parallel port is available through the X15004 connector (26 pins). To have the signals available on a
standard parallel interface connector DSUB25 an adapter cable is required which is offered by KONTRON
(KAB-DSUB25-1, part number 96015-0000-00-0).

Header

Pin

Signal Name

Function

DSUB25

1

/STB

Strobe

1

2

/AFD

Autofeed

14

3

D0

Data 0

2

4

/ERR

Error

15

5

D1

Data 1

3

6

/INIT

Init

16

7

D2

Data 2

4

8

/SLIN

Select in

17

9

D3

Data 3

5

10

GND

Ground

18

11

D4

Data 4

6

12

GND

Ground

19

13

D5

Data 5

7

14

GND

Ground

20

15

D6

Data 6

8

16

GND

Ground

21

17

D7

Data 7

9

18

GND

Ground

22

19

/ACK

Acknowledge

10

20

GND

Ground

23

21

/BUSY

Busy

11

22

GND

Ground

24

23

PE

Paper out

12

24

GND

Ground

25

25

/SLCT

Select out

13

26

VCC

1)

Power +5V

---

Note:

1)

To protect the external power lines of peripheral device make sure that

- the wires have the right diameter to withstand the maximum available current.
- to enclosure of the peripheral device fulfills the fire-protecting conditions of IEC/EN 60950.